Search Results/Filters    

Filters

Year

Banks



Expert Group










Full-Text


Issue Info: 
  • Year: 

    2020
  • Volume: 

    20
  • Issue: 

    7
  • Pages: 

    1801-1814
Measures: 
  • Citations: 

    0
  • Views: 

    424
  • Downloads: 

    0
Abstract: 

Aluminum alloys, due to their high variety and favorable mechanical properties, are widely used in industries. Aluminum alloy 111H-5754 due to its properties such as high strength to weight ratio, ductility, toughness, and corrosion resistance, are applied in the manufacture of automotive body, offshore, and offshore oil equipment. The presence of 3% magnesium in the chemical structure of this alloy makes it susceptible to heat and therefore, it is not possible to perform most of the traditional machining processes on it. Water jet machining with abrasive particles (AWJM), because of the use of water and abrasive particles as cutting tools, can be a good method for machining these materials. In the present study, the effect of water jet and abrasive particle machining process parameters, including water jet pressure, traverse speed and loading coefficient on surface roughness, Angle of Striation, and burr formation in aluminum alloy 111H-5754 samples is discussed. The results showed that after traverse speed, water jet pressure and loading coefficient have the most effects on the surface quality characteristics, respectively. So, for a loading factor of 45% and a jet pressure of 300MPa, increasing the traverse speed from 200 to 300mm/min, the surface roughness value in the smooth area is about 50%, and the Angle of Striation of the lines in the rough area, increased by about 25%.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 424

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    1395
  • Volume: 

    1
Measures: 
  • Views: 

    532
  • Downloads: 

    0
Abstract: 

آزمایش های طیف سنجی گاما برای اندازه گیری فعالیت هسته های گامازا در نمونه های محیطی و صنعتی انجام می شوند. با توجه به تعدد نمونه ها (از لحاظ شکل هندسی، ترکیبات و غیره)، نمونه های استاندارد متعددی مورد نیاز است. در بیش تر مواقع تهیه مرجع گران و بعضا دست نیافتنی است. بنابراین، یک روش محاسباتی جایگزین برای محاسبه بازده دستگاه طیف سنجی گاما بیش تر احساس می شود. در این مقاله، ابتدا بازده تجربی چشمه های نقطه ای استاندارد توسط یک آشکارساز HPGe اندازه گیری شده است. سپس، بر اساس نمودار بازده تجربی یاد شده کالیبراسیون (درجه بندی) بازده آشکارساز HPGe برای نمونه های مختلف با استفاده از کد محاسباتی Angle بدست آمده اند. نتایج حاصل از شبیه سازی با نتایج تجربی مقایسه شده اند.

Yearly Impact:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 532

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0
Issue Info: 
  • Year: 

    2017
  • Volume: 

    60
  • Issue: 

    1
  • Pages: 

    369-375
Measures: 
  • Citations: 

    0
  • Views: 

    1026
  • Downloads: 

    0
Abstract: 

Introduction: Multiple sclerosis is the most common chronic neurological disorders, disabling young and active people in society and is determined by frequency and unpredictability of recurrence and improvement over time, MRI is the modality of choice in patients with suspected multiple sclerosis. The aim of this study was comparison of subcalosal Striation and Dawson fingers in MRI of multiple sclerosis patients.Subjects & Methods: This study was cross-sectional, 61 patients with MS who referred to radiology department of Imam Reza Hospital were tested with brain MRI. Signs of subcalosal Striation and Dawson fingers in MRI Were assessed. The software of SPSS 21 was used for statistical analysis.Results: The prevalences of subcalosal Striation and fingers Dawson in MS patients are significantly different, respectively 100% and 91.8% (P<0.05). The prevalences of subcalosal Striation and fingers Dawson in MS patients older than 35 years are significantly different, respectively 100% and 88% (P<0.05). The prevalences of subcalosal Striation and fingers Dawson in Female MS patients are significantly different, respectively 100% and 89.3% (P<0.05).Conclusion: subcalosal Striation as a criterium in the radiological diagnosis of MS can be helpful in making more accurate diagnosis of MS.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 1026

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2014
  • Volume: 

    9
  • Issue: 

    4
  • Pages: 

    439-443
Measures: 
  • Citations: 

    0
  • Views: 

    246
  • Downloads: 

    3
Abstract: 

Purpose: To quantitatively analyze central corneal thickness (CCT) in patients with primary Angle closure glaucoma (PACG) and primary open‑Angle glaucoma (POAG), and to evaluate its correlation with severity of glaucoma.Methods: In this retrospective study, records of patients with previously diagnosed POAG or PACG at a tertiary glaucoma service were reviewed. CCT was measured by ultrasound pachymetry. Mean deviation (MD) on visual field (VF) testing was recorded for glaucoma severity determination. CCT and age‑ and sex‑adjusted CCT were compared among the study groups using Student’s t‑test and analysis of covariance (ANCOVA), respectively. Univariate and multivariate regression models were used for correlation of age, MD and CCT.Results: A total of 115 patients with PACG, 215 with POAG, and 100 normal controls were included with mean age of 64.1±10.4, 59.9±10.5, and 62.04±10.80 years, respectively. CCT was thicker in PACG eyes (545.5±46.1 mm) as compared to POAG eyes (531.7±37.3 mm) and controls (531.0±38.3 mm) even after age and gender adjustment (ANCOVA, P=0.05). CCT was found to decrease with increasing age only in the POAG group (b=-0.57, P=0.01). Disease severity (MD of VF) was significantly and inversely correlated with CCT in both POAG and PACG eyes (b=1.89, P=0.02; and b=1.38, P=0.04, respectively) after age and sex correction.Conclusion: PACG eyes had thicker CCT as compared to POAG and normal healthy eyes in Iranian subjects. Severity of the disease was inversely correlated with CCT in eyes with both POAG and PACG.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 246

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 3 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2011
  • Volume: 

    14
  • Issue: 

    5 (52)
  • Pages: 

    465-471
Measures: 
  • Citations: 

    0
  • Views: 

    378
  • Downloads: 

    226
Abstract: 

Objective (s): The objective of this study was to document and explain bilateral differences in the Q Angle.Materials and Methods: Two hundred limbs of healthy adult Indian volunteers were studied. The Q Angle was measured using a goniometric method with the subjects supine, quadriceps relaxed and lower limbs in neutral rotation. The relative lateral placement of the tibial tuberosity with respect to the centre of the patella was measured. Appropriate statistical tests were used to determine the bilateral variability in the Q Angle and the lateral placement of the tibial tuberosity. Inter-observer variation of the above mentioned parameters were studied in twenty limbs.Results: The average Q Angle value of all the 200 limbs was 12.73oC; the mean value on the right was 12.86oC and 12.60oC on the left. When the Q Angle and the lateral placement of the tibial tuberosity were considered in pairs a significant difference was noted in males. The Q Angle value on the right side was more often greater than the left. The relative lateral placement of the tibial tuberosity showed a significant positive correlation with the Q Angle. The intra-class correlation coefficient was 0.66 for the Q Angle and 0.8 for the lateral placement of the tibial tuberosity.Conclusion: The present study shows that bilateral variability in the Q Angle could be attributed to an alteration of the relative placement of the tibial tuberosity with respect to the centre of the patella.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 378

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 226 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Author(s): 

WEINREB R.N. | KHAW P.T.

Journal: 

LANCET

Issue Info: 
  • Year: 

    2004
  • Volume: 

    363
  • Issue: 

    9422
  • Pages: 

    1711-1720
Measures: 
  • Citations: 

    1
  • Views: 

    144
  • Downloads: 

    0
Keywords: 
Abstract: 

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 144

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2003
  • Volume: 

    15
  • Issue: 

    1 (31)
  • Pages: 

    7-11
Measures: 
  • Citations: 

    0
  • Views: 

    293
  • Downloads: 

    0
Abstract: 

Objective and Importance: The authors reported a case of plasmocytoma involving the cerebellopontine Angle (CPA), which is a rare presenting location of intracranial extramedullary plasmocytoma. Clinical presentation: The patient was A 55-years-old woman who complained of vertigo and tinnitus for one year before. Admission, Neurological examination showed impairment of cerebellar tests. CT scan revealed a large mass lesion in the left CPA region. Intervention: The patient underwent a left retromastoid craniectomy and resection of the tumor. Histopathological studies of biopsy revealed plasmocytoma. Other studies including bone isotope scan and bone marrow aspiration did not show involvement of other parts of the body. Within 6 months of follow up there was No sign of progression of the tumor in CT scan. Conclusion: There are few reports of CPA solitary plasmocytoma. There is a potential risk for error in diagnosis in imaging and pathology. The current treatment is subtotal or radical resection combined whit radiotherapy.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 293

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2015
  • Volume: 

    8
  • Issue: 

    4
  • Pages: 

    1-10
Measures: 
  • Citations: 

    0
  • Views: 

    2418
  • Downloads: 

    0
Abstract: 

Background and Aim: Muscle fascicle length and pennation Angle can be non-invasively studied by applying methods like ultrasonography. The aim of this study was to introduce fascicle length and fascicle Angle for the estimation of the strength of skeletal muscle by using ultrasonography.Materials and Methods: The data of this study have been driven from pubmed and authoritative references available on the internet and in libraries. In all fifteen full text articles and 30 abstracts have been collected and reviewed. Keywords such as: muscle, fascicle, pennation Angle, force and ultrasonography were searched to fulfill the purpose of this study.Results: Detailed information about the Angles of pennation and fascicles length are important to predict muscle force. It has been suggested that changes in muscle pennation Angles are positively correlated to the length of fascicle in a muscle contraction. While muscle thickness may in some case be remained constant in this relation.Conclusion: Real-time ultrasonography is a noninvasive procedure to monitor the architecture of the living muscle at rest and during static and dynamic sets. It is a valuable measurement tool to estimate muscle force by measuring the muscle architecture parameters such as Angle of pennation and fascicle length.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 2418

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2019
  • Volume: 

    16
  • Issue: 

    5
  • Pages: 

    355-361
Measures: 
  • Citations: 

    0
  • Views: 

    156
  • Downloads: 

    174
Abstract: 

Introduction: Dose distribution can be affected by diverse parameters, such as beam orientations, and collimator Angles. These parameters should respect and maintain the international recommended levels during the realization of the quality assurance protocols of linear accelerators. This study aimed at evaluating the dosimetric effects on treatment quality considering the mechanical error fluctuations in the recommended range. Material and Methods: This study included ten patients with head and neck cancer. All of them were treated using three-dimensional conformal radiotherapy with the simple 3-field classic technique. Initially, an optimized treatment plan was computed for each patient. Afterward, similar calculations were executed by varying isocenter position, gantry and collimator Angles. Eventually, dosimetric evaluations based on dose-volume histograms were studied and analyzed by Wilcoxon signed rank test for each plan. Results: The analysis of the dose-volume histograms of tumor volumes and organs at risk, as well as the dosimetry calculation, revealed that the small errors of 0. 5° in gantry and collimator Angles have minimal effects on dose distribution. However, the variation in isocenter coordinating up to 1 mm may influence the patients’ treatment quality, particularly in the spinal cord and the brainstem, in which Wilcoxon's test showed significant effects in all plans. Conclusion: According to the results, the quality of the treatment plans is almost insensitive to the errors of the gantry and the collimator Angles of the order 0. 5° though it is relatively sensitive to isocenter errors (1 mm). These should be reduced in order to avoid overdose when applying the conventional 3-field technique.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 156

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 174 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Author(s): 

Journal: 

WORLD NEUROSURGERY

Issue Info: 
  • Year: 

    2018
  • Volume: 

    112
  • Issue: 

    -
  • Pages: 

    18-24
Measures: 
  • Citations: 

    1
  • Views: 

    79
  • Downloads: 

    0
Keywords: 
Abstract: 

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 79

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button